Enquire online 24/7 · On site 7am–6pm
Duracell inverter, generation meter and isolators neatly installed above two Duracell home battery units
Selenium Energy · Winchester & Hampshire

EICR Electrical SafetyInspections in Winchester& Across Hampshire

A proper inspection and test of your installation, with a report you can actually read and a clear price for anything that needs putting right. City & Guilds 2391 qualified, NAPIT registered, guaranteed workmanship on any remedial work.

City & Guilds 2391 inspection and testing · NAPIT registered under Part P · 25 years as a qualified electrician · 2-year workmanship guarantee on remedial work.

C&G 2391

Inspection and testing qualification held by Steve personally.

25 years

Every observation judged by an electrician of 25 years.

Plain English

Coded report explained in language you can act on.

NAPIT · Part P

Remedial work certified to the 18th Edition of BS 7671.

An EICR tells you the true condition of your electrics: in writing

An Electrical Installation Condition Report is a formal inspection and test of a fixed electrical installation. It examines the consumer unit, earthing and bonding, every accessible accessory and every circuit, then measures the things that cannot be seen: insulation resistance, earth fault loop impedance, polarity, continuity and RCD trip times. The result is a report with observations coded by severity, so you know what is dangerous, what is potentially dangerous, what should be improved and what needs further investigation.

Selenium Energy carries out EICRs for homeowners, landlords and businesses across Winchester and Hampshire. Steve holds City & Guilds 2391 for inspection and testing, is NAPIT registered under Part P, and has 25 years' experience as a qualified electrician: which matters, because coding an observation is a judgement, and the difference between a C2 and a C3 can be the difference between a few hundred pounds and a few thousand.

You will get a completed report with recorded test results, a schedule of circuits and a written explanation of each observation in language that makes sense. Where remedial work is required, it is quoted separately as a fixed price so you can decide what to do and in what order, not presented as a single unavoidable bill.

Landlords in England need a satisfactory report for rented property, renewed at least every five years and at change of tenancy where required. Owner-occupiers are advised to have an EICR every ten years, and always before buying a property or after work by an unknown contractor.

You need an EICR if

  • You let residential property and need a satisfactory report and certificate for your tenancy.
  • You are buying a house and want the electrics assessed before you commit.
  • The installation has never been tested, or the last report is more than five to ten years old.
  • You have inherited work by an unknown contractor with no certification.
  • Circuits trip intermittently, accessories are warm or discoloured, or there is a smell of hot plastic.
  • You run a commercial premises and need documented evidence of electrical condition.

What an untested installation hides

Electrical deterioration is silent. Insulation degrades, terminations loosen with thermal cycling, and damp works into outbuilding wiring: none of which shows on a light switch until the day it fails.

Shock and fire risk you cannot see

Deteriorated insulation, broken earth continuity and loose terminations do not announce themselves. They are found by measurement, and until they are found they are live faults waiting on a coincidence.

Legal and letting exposure

Rented residential property in England requires a satisfactory report renewed at least every five years. Without one, a landlord is exposed to enforcement action and to difficult questions if there is ever an incident.

Escalating remedial costs

A single deteriorated circuit caught early is a small job. Left until several circuits are affected and the board will no longer hold, it becomes a partial or full rewire.

Common mistakes around EICRs

  • Treating an EICR as a paperwork exercise and buying the cheapest report available.
  • Accepting a report with no measured test results recorded, only ticks.
  • Not reading the codes: C1 and C2 make a report unsatisfactory, C3 and FI do not.
  • Assuming every observation must be fixed by the inspector who found it.
  • Skipping the follow-up work but keeping the report on file as if it were satisfactory.
  • Booking an inspection with no access to the loft, consumer unit or outbuildings, so the report is limited by exclusions.

How your inspection runs

A domestic EICR is normally a single visit, with the report and any remedial quote following shortly after.

  1. 1

    Booking and access

    We agree scope, the property's circuits, and access to the board, loft and any outbuildings, plus an isolation window since testing requires the power off for periods.

  2. 2

    Visual inspection

    The consumer unit, earthing and bonding, accessories, cable routes and any signs of overheating, damage or unsafe DIY alterations are inspected and recorded.

  3. 3

    Dead and live testing

    Continuity, insulation resistance and polarity measured with the supply isolated, then earth fault loop impedance and RCD/RCBO trip times measured live, circuit by circuit.

  4. 4

    Coding and diagnosis

    Each observation is coded C1, C2, C3 or FI, with the reason stated. Nothing is coded to justify selling work, and nothing safety-critical is played down.

  5. 5

    Report and remedial quote

    You receive the completed report with test results and a schedule of circuits, plus a separate fixed-price quote for any remedial work, typically within 48 hours.

  6. 6

    Remedial work and certification

    If you go ahead, remedial work is certified to the 18th Edition of BS 7671 under NAPIT, notified under Part P where required, and covered by our 2-year workmanship guarantee.

What you get from an EICR done properly

Measured evidence, not opinion

Every circuit's readings are recorded, so you have documented proof of condition rather than a signature on a form.

A report you can act on

Observations are explained in plain English with the reason for each code, so you can prioritise sensibly rather than guess.

Fair, experienced coding

Coding is a judgement, and 25 years on the tools is what stops genuine hazards being downgraded or trivial items inflated into a large invoice.

Compliance you can hand over

Landlords receive a report and certificate formatted to pass straight to an agent, tenant or local authority.

Remedial work priced separately

Any work needed is quoted as a fixed price you can compare or decline: the inspection is not a route into an open-ended job.

Guaranteed follow-up work

If we carry out the remedials, they are certified under NAPIT and Part P and guaranteed for two years.

EICRs in detail: codes, testing and scope

Understanding how a report is built makes it far easier to judge whether the one you are holding is any good.

What the codes mean

C1 means danger is present and there is a risk of injury: immediate action is required, and we will make it safe before leaving where that is possible. C2 means potentially dangerous, no immediate danger under normal conditions, but urgent remedial action is needed, for example a missing earth or absent RCD protection where the regulations now require it. Either code makes the report unsatisfactory.

C3 means improvement recommended: the installation is safe but does not meet the current standard, for example an older board type that is functioning correctly. A C3 does not make a report unsatisfactory and does not have to be actioned, though it is often worth planning for. FI means further investigation is required, because something was found that could not be resolved within the scope of the inspection.

A report should also record its extent and limitations. Sample sizes, inaccessible areas and circuits not tested must be stated, because a report on a partly inspected installation says less than it appears to.

  • C1: danger present, immediate action
  • C2: potentially dangerous, urgent remedial action
  • C3: improvement recommended, report stays satisfactory
  • FI: further investigation required
  • Extent and limitations recorded explicitly
  • Schedule of circuits and measured test results included

The tests behind the report

Dead tests happen with the supply isolated: continuity of protective conductors and ring final circuits, insulation resistance between conductors, and polarity throughout. Insulation resistance is the measurement that reveals ageing cable, damp ingress and damage inside walls: the faults you cannot see and cannot infer from behaviour.

Live tests follow: earth fault loop impedance, which confirms a fault would disconnect quickly enough, prospective fault current, and RCD or RCBO trip times measured against their rated performance. An RCD that operates but takes too long is not protecting anybody, and only a timed test finds it.

Results are recorded per circuit on the schedule of test results. Any report handed over without those figures is not an EICR in any meaningful sense, whatever the front page says.

Frequency, tenancies and property purchases

For rented residential property in England, a satisfactory report is required and must be renewed at least every five years, with a copy provided to tenants and to the local authority on request. Where a report is unsatisfactory, remedial work must be completed and evidence retained.

Owner-occupied homes should be inspected around every ten years, and always when buying a property, after an extension or renovation, or when work has been carried out by a contractor who left no certification. Commercial premises are typically inspected on a shorter cycle depending on use and environment.

A pre-purchase EICR is one of the cheapest pieces of due diligence available on a house. Discovering that a property needs a board change and a partial rewire before you exchange is worth considerably more than the cost of the inspection.

  • Rented residential property: at least every five years
  • Owner-occupied homes: around every ten years
  • Before purchase, after renovation, or after uncertified work
  • Commercial premises: cycle set by use and environment

Remedial work and what usually comes up

The observations we record most often are absent or inadequate RCD protection, undersized or missing main bonding to gas and water, obsolete boards and enclosures, deteriorated cable in outbuildings and lofts, unsafe DIY alterations in kitchens and gardens, and accessories showing heat damage.

Most are straightforward to correct: a consumer unit upgrade addresses a large share of C2 observations in one visit, bonding upgrades are usually a half-day, and localised cable renewal is far cheaper than a full rewire. Where deterioration is widespread, full or partial rewiring is the honest recommendation, and we will say so rather than sell repeated patch repairs.

Remedial work is quoted as a fixed price separate from the inspection fee, and you are free to have another electrician carry it out. If we do it, you get certification to the 18th Edition under NAPIT, Part P notification where required, and our 2-year workmanship guarantee.

Frequently asked questions

How much does an EICR cost in Winchester?

Inspection cost depends on the number of circuits and the size of the property, so we quote after a short conversation about the installation rather than publishing a single figure. Quotes are free and any remedial work is priced separately as a fixed price.

How long does an inspection take?

A typical domestic EICR takes a few hours, longer for larger properties or installations with many circuits. Parts of the testing require the power off, so we agree isolation periods with you when booking.

How often do I need one?

Rented residential property in England needs a satisfactory report renewed at least every five years. Owner-occupied homes are advised around every ten years, and always before purchase or after uncertified work.

What happens if the report is unsatisfactory?

Any C1 or C2 observation makes a report unsatisfactory. You receive a fixed-price quote for the remedial work, and once it is completed and certified the installation can be signed off as satisfactory. C3 observations are recommendations and do not have to be actioned.

Do I have to use you for the remedial work?

No. The report is yours and you can take it to any qualified electrician. We quote remedial work as a separate fixed price precisely so you can compare it.

Who carries out the inspection?

Steve, who holds City & Guilds 2391 for inspection and testing, is NAPIT registered under Part P, and has 25 years' experience as a qualified electrician.

Is the certificate accepted by letting agents and councils?

Yes. You receive a full report with a schedule of circuits and recorded test results, issued under NAPIT registration, in a form you can pass straight to an agent, tenant or local authority.

Will testing damage my electrics?

No. Testing uses calibrated instruments at controlled voltages. Where a circuit fails a test it was already faulty: the test found it rather than caused it. Sensitive equipment is disconnected before insulation resistance testing as a matter of course.

Can you inspect urgently or out of hours?

Online enquiries are taken 24/7 and on-site work runs 7am to 6pm Monday to Saturday, with emergency call-outs available outside those hours where there is a live safety concern.

Which areas do you cover?

We are based in Winchester and inspect across Hampshire, including Basingstoke, Southampton, Andover, Portsmouth, Salisbury, Reading and Oxford.

Book an EICR and know exactly where you stand

City & Guilds 2391 inspection, recorded test results, plain-English coding and any remedial work quoted as a fixed price. Send your details and Steve will call you back.

Steve Higgins · NAPIT registered · OZEV authorised · 2-year workmanship guarantee · Enquire online 24/7 · On site 7am–6pm

Call SteveFree Quote